- Four outputs for switching and dimming of resistive, inductive and capacitive loads
- Automatic adjustment to leading edge or trailing edge control, depending on the type of load
- Rated operational voltage AC 230 V
- Rated frequency 50 and 60 Hz
- Rated power at +45°C ambient temperature: up to 300 VA per output, up to 1000 VA with bundling of adjacent outputs, without minimum load per output
- Electronic protection per output against overload, short circuit and temperature rise
- Maintenance-free terminals for connection and through-wiring of untreated single-core, stranded or multi-core conductors, 0.5...2.5 mm2
- Manual operation buttons on the device for switching, dimming and activation of direct mode operation
- Bus-powered electronics
- DIN-rail mounted device for mounting on rail TH35 according to DIN EN 60715
- Building site function for bundling the outputs and switching the building site lighting without prior configuration of the device via ETS
- Object for surveillance of device function
- Object for retrieval of status values
- Per output with selectable operation mode (normal mode, one- or two-level timer mode, blinking)
- Adjustable ON-/OFF-delay
- Object Central Switching with separately configurable on/off delay selectable
- Separately adjustable dimming time from 0% to 100% for switching on/off and dimming brighter/darker
- Switch an output on or off by dimming brighter/darker
- Configurable dimming curves for optimization of the dimming operation of lights
- Additional status object switching and/or status object dimming value
- Additional object for dimming with individually adjustable dimming time
- Configurable maximum and minimum dimming value via parameter and object
- Selectable object for limiting the maximum dimming value
- Selectable object for reporting of overload, short circuit and temperature rise
- Adjustable blocking time for sending status objects after restart and bus voltage recovery
- Integrated 8-bit scene control, linking of the output in up to 8 scenes
- Additional night mode object for time-limited switching on the output at night
- Post-triggering of the On period (On period extension) in time switch mode up to a selectable maximum On period extension via repeated (2x, 3x, 4x, 5x) post-triggering
- Selectable warning signal prior to imminent switching-off by brief off and on switching (flashing) or by cutting the current dimming value in half at night or in time switch mode
- Selectable counting with threshold monitoring: operating hours, load cycles